GET_CALCULATION_FAN_ALONE_PC
This function is used to determines the functional values of the fan in a given operating point.
Method Call:
Result = GET_CALCULATION_FAN_ALONE_PC(InputString, OutputBuffer)
Input:
Position | Name | Description | Example Value | Required |
---|---|---|---|---|
0 | fan idno | key for related measurement of the fan | 126873 | Y |
1 | option | pressure type 0 = V u. Pfa(static) 1 = V u. Ptot(total) | 0 | N |
2 | mounting | installation type (always 0) 4 = Exception with wire guard (only RadiPac) | 0 | N |
3 | air density (Rho) | density of the air [kg/m³] | 1,2 | N |
4 | altitude | altitude [m] (only required if Rho is not given) | 0 | N |
5 | air temperature | temperature of the air [°C] (only required if Rho is not given) | 20 | N |
6 | pressure difference | pressure difference (stat/tot) depending on pressure type {Input1} [Pa] | 600 | Y |
7 | air volume | air volume [m³/s] | 0,4444 | Y |
8 | width | width installation space [mm] | 1200 | N |
9 | height | height installation space [mm] | 1200 | N |
10 | calculation method | calculation method rlt = calculation installation losses with rlt method ebmpapst = calculation installation losses with ebmpapst method empty = without calculation Installation losses | ebmpapst | N |
11 | speed reserve | speed reserve [%] | 0 | N |
12 | return format | return format Json T = JSON F = CSV | F | Y |
13 | buffer size | size of the output buffer | 8000 | N |
14 | not used | |||
15 | fan type | part number of the fan | R3G400AY8701 | N |
16 | speed factor | 0.1 > speed factor <= 1 |
| N |
Example InputString
126873;0;0;1,2;0;20;600;0,44444;1200;1200;ebmpapst;0;F;8000;;K3G560PB22C1;; |
Output:
The DLL returns the results in the variable "OutputBuffer":
CSV-Format
JSON-Format